Title 

Cannot change version for some WOs.

Severity 

Information message, logged for the environment. Table: JOURNAL.

Data 

IDs of the WOs for which the item version could not change.

Explanation 

Changing the item version is impossible in the following cases:

  1. The item versions do not have the same BOM.

  2. One of the WO's operations is the ending point of a fixed link.

  3. One of the WO's operations is the starting point of a fixed link.

  4. One of the WO's operations is the ending point of a synchronization link.

  5. One of the WO's operations is the starting point of a synchronization link.

  6. The WO is in progress or complete.

  7. The WO has a fixed supply.

Action

  • Case 1: Select a different item version.

  • Case 2 & 3: Remove the fixed link, change the item version, and then recreate the fixed link.

  • Case 4 & 5: Delete the synchronization link, and then recreate it after you change the version.

  • Case 6: You cannot change item version in this case.

  • Case 7: Unfix the WO supply.